The rapid development of AI servers, high-performance GPU clusters, and high-density data centers is placing increasing demands on conventional air-cooling systems. Limitations in heat dissipation, energy consumption, and rack space are encouraging the adoption of liquid cooling technologies.
Among these technologies, immersion cooling is attracting attention as a potential solution for selected high-power-density applications.
According to market data from CCID Consulting's 2025–2026 China Liquid-Cooled Data Center Market Report:
| Indicator | Market data |
|---|---|
| China's liquid-cooled data center market in 2025 | RMB 15.98 billion |
| Year-on-year growth in 2025 | 45.2% |
| Forecast market size in 2028 | RMB 47.04 billion |
The 45.2% figure represents year-on-year growth in 2025. The RMB 47.04 billion figure is a market forecast for 2028, not an already achieved sales value.
Market expansion is creating new demand for thermal management materials. Immersion cooling systems require a fluid that can directly contact suitable server components, transfer heat efficiently, and maintain electrical and chemical stability over extended operating periods.
Can conventional silicone oil be used for data center cooling?
The answer is: it can be evaluated, but not every silicone oil is suitable. The more relevant material category is specially engineered modified silicone-based dielectric coolant.
Immersion cooling is a thermal management method in which server boards, processors, and other suitable electronic components are submerged in a liquid with electrical insulating properties.
The liquid directly contacts heat-generating components and removes the heat produced during operation.
Unlike conventional air cooling, immersion cooling does not rely primarily on air movement to remove heat. Instead, it uses the liquid's heat capacity, thermal properties, and circulation to transfer heat away from the equipment.
The basic process is:
Electronic components generate heat during operation.
The coolant directly contacts the heat-generating components and absorbs heat.
The heated liquid moves through natural convection or a circulation pump.
Heat is transferred to an external cooling system through a heat exchanger.
The cooled liquid returns to the equipment area, forming a continuous circulation loop.
| Comparison | Single-phase immersion cooling | Two-phase immersion cooling |
|---|---|---|
| Operating principle | The coolant remains liquid and transfers heat through circulation and heat exchange | The coolant boils, vaporizes, and condenses back into liquid |
| Main heat transfer mechanism | Sensible heat transfer and liquid circulation | Latent heat of phase change |
| Main fluid requirements | Dielectric properties, thermal stability, suitable viscosity, material compatibility | Dielectric properties, suitable boiling point, latent heat, vapor pressure, and sealing performance |
| Candidate fluids | Silicone-based fluids, synthetic hydrocarbons, esters, and other dielectric liquids | Specialized fluids with suitable boiling and phase-change characteristics |
This article focuses mainly on single-phase immersion cooling, where modified silicone-based fluids are one of the material categories worth evaluating.
Conventional silicone oils have certain electrical insulating, thermal, and chemical properties. However, immersion cooling places more demanding requirements on the fluid.
The most suitable candidates are generally not untested industrial silicone oils. They are modified silicone-based liquids designed with specific molecular structures, viscosity, purity, and performance requirements for immersion cooling.
Immersion cooling fluids must provide adequate electrical insulation to avoid unacceptable leakage currents or short circuits when they directly contact energized electronic components.
Siloxane liquids generally have useful dielectric characteristics. Specially designed silicone-based dielectric fluids can therefore be considered for immersion cooling.
However, several distinctions are important:
An insulating liquid does not have absolutely zero electrical conductivity.
Dielectric strength and volume resistivity can be affected by moisture, ionic impurities, contaminants, and operating conditions.
Different silicone oil grades do not necessarily have identical electrical properties.
Therefore, a product should not be considered suitable for direct server immersion simply because it is labeled as silicone oil.
The thermal performance of an immersion coolant cannot be judged by thermal conductivity alone.
Other important parameters include:
Thermal conductivity
Specific heat capacity
Density
Viscosity and its temperature dependence
Liquid circulation and natural convection
Long-term thermal stability
Viscosity is particularly important. Excessively high viscosity may increase circulation resistance and affect pumping or natural convection. Lower viscosity may be beneficial for flow, but volatility, sealing design, and system conditions must also be considered.
A 2026 comparative study of single-phase immersion cooling fluids evaluated silicone oils, synthetic hydrocarbons, esters, and fluorinated liquids. The results showed that thermal conductivity, density, and dynamic viscosity all influence cooling performance.
This demonstrates why a single physical property cannot determine the overall suitability of an immersion coolant.
Data centers are generally designed for continuous operation. A coolant must therefore maintain stable properties over extended periods rather than simply providing good short-term heat transfer.
Important factors include:
Viscosity changes at elevated temperatures
Oxidation and thermal degradation
Volatile loss
Changes in color and appearance
Accumulation of moisture and contaminants
Formation of deposits or insoluble materials
Specially designed modified silicone-based coolants can be formulated to address these requirements.
However, ordinary methyl silicone oil should not automatically be assumed to provide the same long-term performance. Product-specific testing remains necessary.
One major difference between immersion cooling and conventional industrial lubrication is that the coolant may remain in direct contact with many materials inside a server.
These may include:
Metals and metal coatings
PCB materials and surface finishes
Cables and insulating materials
Plastics and connectors
Rubber seals
Adhesives and other auxiliary materials
If a coolant is incompatible with a material, it may cause swelling, shrinkage, softening, cracking, extraction, or other changes.
Therefore, thermal stability alone is not enough. Compatibility testing should cover the actual materials used in the equipment.
Modified silicone-based immersion cooling fluids are no longer purely a laboratory concept.
Dow's DOWSIL™ ICL-1000 Fluid is a modified polysiloxane liquid specifically designed for data center immersion cooling.
According to Dow's publicly available product information, the fluid has the following characteristics:
Based on modified polysiloxane
Intended for immersion or spray cooling of data center servers
Designed for thermal management performance
Offers thermal stability and oxidation resistance
Designed with compatibility with server equipment and related materials in mind
Has product environmental attributes including very low Global Warming Potential (GWP) and zero Ozone Depletion Potential (ODP)
Its published technical information also provides the following typical properties:
| Parameter | Published typical data for DOWSIL™ ICL-1000 |
|---|---|
| Kinematic viscosity at 40°C | 26 cSt |
| Thermal conductivity at 40°C | 0.18 W/(m·K) |
| Specific heat capacity at 40°C | 2.256 J/(g·K) |
| Open-cup flash point | 240°C |
| Relative density at 25°C | 0.86 |
| Dielectric constant at 1 kHz | 2.276 |
These are typical values from published technical information, not purchasing specifications for every batch. They should not be used as performance specifications for other silicone-based coolants.
Dow's product demonstrates that specially engineered modified polysiloxane liquids can be developed as commercial media for data center immersion cooling.
However, this does not mean that ordinary methyl silicone oil, phenyl silicone oil, or fluorosilicone oil can directly replace a dedicated immersion cooling fluid.
As China's data center liquid cooling market develops, domestically produced cooling materials are attracting increasing attention.
Jointas Corporation, a Chinese company involved in organic silicone materials, publicly introduced an immersion-grade silicone-based coolant in November 2026, providing another example of domestic product development.
According to publicly available company information, Jointas has an existing silicone oil production line with a capacity of 8,000 tons. The company indicated that this production line could be converted according to market demand and orders.
This information should be interpreted accurately:
The 8,000-ton figure refers to the company's existing silicone oil production-line capacity.
It does not mean that a separate 8,000-ton dedicated immersion coolant production line has already been built.
The actual conversion scope, production volume, and delivery capacity depend on equipment, process requirements, orders, and market demand.
From an industrial perspective, existing silicone oil manufacturing capabilities may provide a foundation for commercialization. However, dedicated immersion coolants still need to meet requirements for purity, stability, consistent quality, and customer validation.
According to Jointas' product information published in November 2026, its immersion-grade silicone-based coolant has the following reported properties:
| Parameter | Company-published data |
|---|---|
| Kinematic viscosity at 40°C | 18–19 cSt |
| Thermal conductivity | 0.14 W/(m·K) |
| Flash point | Above 220°C |
| Pour point | Below -57°C |
The company also described compatibility testing involving seals, cables, plastics, metals, and other server materials.
Its product announcement reported more than 7,200 hours of accelerated immersion testing at 80°C. It also stated that full-system dynamic continuous immersion testing was still in progress at the time of the announcement.
Subsequent public company information discussed production-process validation and delivery capability.
These are company-disclosed product and development updates. Buyers should still request detailed test reports, test methods, sample-batch information, and full-system operating data. Accelerated immersion test hours should not be treated as equivalent to actual server service life.
Domestic substitution in immersion cooling fluids involves more than replacing imported base silicone oils. It also requires progress in several areas.
First: Domestic raw material supply.
Domestic siloxane production and modification technologies can help establish a local supply chain for specialized cooling fluids.
Second: Independent formulation and process development.
Products need to be optimized for viscosity, dielectric properties, thermal stability, low-temperature fluidity, and material compatibility.
Third: Lower supply-chain and lifecycle costs.
Domestic products may gain opportunities if they can meet project requirements for performance, reliability, and long-term operating costs.
Fourth: Long-term application data.
Immersion cooling fluids are not one-time consumables. Long-term operation, maintenance, replenishment, monitoring, and replacement costs all influence purchasing decisions.
Therefore, the key to domestic substitution is not simply launching a product or announcing production capacity. It is the ability to supply stable, reliable, and verifiable products over time.
For data center operators, server manufacturers, and liquid cooling system integrators, coolant selection should not be based only on thermal conductivity or price.
The following six categories deserve attention.
| Selection category | Main parameters | Why they matter |
|---|---|---|
| Low-temperature performance | Pour point, low-temperature viscosity, start-up flowability | Affects transport, circulation, and start-up in cold environments |
| Thermal management | Thermal conductivity, specific heat, density, viscosity | Determines heat transfer and circulation performance |
| Electrical performance | Dielectric strength, volume resistivity, electrical conductivity | Related to electrical safety during direct contact with electronic components |
| Safety | Flash point, combustion behavior, toxicology, occupational exposure data | Relevant to storage, transportation, handling, and fire safety |
| Long-term stability | Oxidation, thermal stability, volatile loss, contamination control | Influences fluid life and maintenance costs |
| Material compatibility and environmental compliance | Compatibility with seals, plastics, metals, and PCBs; PFAS, GWP, and ODP | Affects equipment reliability and regulatory compliance |
Pour point is a test-based indicator of the temperature at which a liquid loses its ability to flow under specified conditions.
For data center cooling systems, other factors are also important:
Actual low-temperature viscosity
Pumping capability
Low-temperature start-up performance
Minimum ambient temperature at the installation site
Pipework and heat exchanger design
A low pour point does not necessarily mean that the coolant will circulate efficiently at that temperature.
Higher thermal conductivity generally indicates better heat transfer under the same temperature gradient.
Specific heat capacity describes how much heat a unit mass of liquid can absorb when its temperature increases by a certain amount.
Both properties influence thermal management. However, viscosity, density, flow rate, heat exchanger design, and server heat flux must also be considered.
The fluid with the highest thermal conductivity is not automatically the best coolant for the entire system.
For a coolant that directly contacts electronic components, dielectric performance is essential.
Suppliers should be asked to provide:
Dielectric strength
Volume resistivity
Electrical conductivity
Dielectric constant
Moisture-control requirements
Limits for contaminants and ionic impurities
These properties should be assessed against relevant test methods and server manufacturer requirements.
Coolant safety cannot be determined by flash point alone.
Other important factors include:
Flash point and combustion characteristics
Thermal decomposition temperature and decomposition products
Toxicological information
Skin contact and inhalation exposure risks
Storage and transportation requirements
Spill response and fire protection procedures
Even a liquid with a high flash point should not be described as incapable of burning under all conditions.
Compatibility testing should cover actual materials used in the equipment, including seals, cables, plastics, metals, PCBs, and other auxiliary components.
Possible test parameters include:
Mass change
Dimensional change
Hardness change
Tensile property changes
Appearance and surface condition
Extractable substances
Electrical performance after prolonged contact
Laboratory material tests are important, but they cannot fully replace full-system dynamic operating validation.
As global attention to PFAS (per- and polyfluoroalkyl substances) increases, coolant suppliers need to pay closer attention to product composition and regulatory compliance.
Some traditional fluorinated dielectric coolants, such as perfluoropolyether (PFPE) products, offer useful chemical stability and electrical insulation properties. However, their PFAS status, environmental persistence, and applicable regulatory requirements need careful evaluation.
Non-fluorinated silicone-based coolants offer another material route for data center applications.
Several distinctions are important:
“Silicone-based” does not automatically mean “PFAS-free.”
“Fluorinated” alone is not enough to determine the precise regulatory classification of every product in every jurisdiction.
The complete chemical structure, CAS information, supplier declarations, and target-market regulations should be reviewed.
Low GWP, zero ODP, and PFAS-free are different environmental attributes and cannot be used interchangeably.
For products intended for markets with strict PFAS controls, suppliers should provide clear PFAS composition declarations, the definition used, and any required testing or regulatory compliance documents.
In discussions of data center cooling, fluorosilicone oil, fluorosilicone rubber, and perfluoropolyether coolant are sometimes incorrectly treated as the same material.
In fact, they have different molecular structures, physical forms, and application roles.
| Material | Physical form | Main characteristics | Position in liquid cooling |
|---|---|---|---|
| Ordinary methyl silicone oil | Liquid | Lubrication, dielectric properties, and certain thermal characteristics | Some grades may be evaluated as candidate base fluids but require dedicated validation |
| Modified silicone-based coolant | Liquid | Designed for thermal management, dielectric properties, and material compatibility under immersion conditions | Important candidate route for single-phase immersion cooling |
| Fluorosilicone oil | Liquid | Compatibility advantages with selected oils and chemical media | Specialty lubrication, special media environments, and formulation modification |
| Fluorosilicone rubber (FVMQ) | Elastomer | Used in selected fuel-contact and low-temperature sealing applications | May be evaluated for cooling-system seals; it is not a coolant |
| Perfluoropolyether (PFPE) | Liquid | Specific chemical stability and dielectric characteristics | Used in certain specialized fluorinated dielectric coolant systems |
The main value of dedicated modified silicone-based coolants includes:
Dielectric performance designed for immersion cooling
Formulation flexibility for thermal management
Potential to reduce dependence on traditional fluorinated dielectric fluids
Opportunities for optimization around material compatibility and long-term operation
If a product has been fully assessed for composition and regulatory compliance and meets the relevant requirements of its target market, it may be developed and marketed as a non-fluorinated coolant option.
The main value of fluorosilicone oil comes from its fluorinated molecular structure and the resulting compatibility with selected chemical media.
It can be useful in specialty lubrication, fuel-contact applications, and specific material modification systems.
However, ordinary fluorosilicone oil is not automatically a dielectric coolant validated for server immersion. Oil resistance alone does not prove suitability for long-term data center thermal management.
In addition, some fluorosilicone structures may fall within broad PFAS definitions. Whether a specific product is covered by a particular regulation must be determined from its chemical structure and the applicable legal framework.
PFPE is a perfluoropolyether, with a molecular structure different from fluorosilicone oil.
Certain PFPE products offer useful chemical stability and dielectric performance and have been used in specialized electronic cooling and two-phase immersion cooling applications.
However, environmental persistence, PFAS regulations, cost, and supply-chain risks need separate evaluation.
Therefore, not all fluorinated dielectric liquids should be treated as the same material, and PFPE coolant data should not be replaced with fluorosilicone oil data.
Direct use without validation is not recommended.
Ordinary dimethyl silicone oil has certain dielectric and thermal properties, but it may not meet all requirements for server immersion cooling, including thermal management, low-temperature flowability, dielectric performance, purity, material compatibility, and long-term stability.
A dedicated product with a clearly stated immersion cooling application and supporting test data is preferable.
This cannot be determined from the base material name alone.
Actual compatibility testing is required to assess whether PCBs, cables, plastics, metals, seals, and connectors experience swelling, softening, cracking, extraction, or other changes.
Moisture, ionic impurities, and contaminants in the coolant should also be monitored.
Not necessarily.
Different coolants have different GWP, ODP, PFAS status, toxicology, environmental persistence, manufacturing energy requirements, and end-of-life treatment considerations.
A proper comparison should be based on the actual chemical structure, lifecycle information, and target-market regulations.
No direct substitution should be assumed.
The resistance of fluorosilicone oil to selected media does not prove that it meets all requirements for data center cooling. Dielectric properties, thermal management, low-temperature viscosity, volatility, material compatibility, and long-term operating stability must all be evaluated.
No.
A low pour point can help maintain flowability in cold environments, but actual low-temperature viscosity, pumping capability, circulation efficiency, and system start-up conditions are also important.
Pour point alone cannot fully describe low-temperature operating performance.
There is no universal replacement interval for all products and systems.
Actual service life depends on coolant formulation, operating temperature, contamination, equipment sealing, system design, and maintenance practices.
A monitoring program should track viscosity, appearance, moisture, contaminants, dielectric properties, and other key parameters specified by the supplier. Maintenance and replacement should be based on the actual fluid condition.
There is an opportunity for domestic substitution, but domestic origin or production capacity alone does not establish suitability.
A comprehensive comparison should include:
Key physical properties
Dielectric performance
Compatibility with electronic component materials
Long-term operating stability
Full-system test results
Batch-to-batch consistency
Supply capacity and technical support
Total cost of ownership
Final decisions should be based on actual validation by server manufacturers, system integrators, and data center operators.
The growing demand for AI computing is creating new opportunities for data center liquid cooling and the materials used in these systems.
Siloxane materials offer electrical insulation, thermal stability, and molecular design flexibility, providing a technical foundation for developing immersion cooling fluids. Commercial products such as Dow's DOWSIL ICL-1000 also demonstrate that specially engineered modified silicone-based liquids have entered the data center immersion cooling market.
Meanwhile, Chinese manufacturers are advancing the development, production, and application validation of silicone-based immersion coolants. Their future market opportunities will depend on product performance, long-term reliability, cost, and customer validation.
For silicone material manufacturers, this is a promising application area, but product positioning must remain accurate:
Conventional silicone oil is a potential base material. Dedicated modified silicone-based coolant is the product category designed for data center immersion cooling.
Only after systematic testing of thermal management, electrical insulation, safety, material compatibility, and long-term operating performance can a specific grade be considered suitable for data center cooling applications.